Comparative evaluation of displacement of bisphosphonate-coated mini-implants in anterior en-masse retraction – A randomized control split-mouth clinical trial
-
Received: ,
Accepted: ,
How to cite this article: Harikrishnan S, Ramasamy N. Comparative evaluation of displacement of bisphosphonate-coated mini-implants in anterior en-masse retraction – A randomized control split-mouth clinical trial. APOS Trends Orthod. doi: 10.25259/APOS_311_2025
Abstract
Objectives:
The clinical displacement of mini-implants can compromise anchorage during en-masse anterior retraction. This study evaluated whether bisphosphonate-coated mini-implants reduce displacement and enhance retraction efficiency compared to uncoated implants.
Material and Methods:
This was a split-mouth, randomized controlled clinical trial involving 30 patients requiring maximum anchorage following premolar extraction. Patients were randomly assigned to receive either bisphosphonate-coated or uncoated mini-implants in the maxillary arch. Cone beam computed tomography superimposition was used to assess implant displacement in the X (bucco-palatal), Y (mesio-distal), and Z (vertical) axes. Retraction space closure was measured using three-dimensional digital models at 3 and 6 months.
Results:
Miniscrew displacement was significantly lower in the bisphosphonate-coated group in the mesio-distal (Y) direction (p < 0.05). The coated group also showed a significantly greater rate of space closure at both 3 and 6 months (p < 0.05).
Conclusion:
Bisphosphonate coating reduces mini-implant displacement and may enhance the rate of anterior retraction when used in maximum anchorage cases.
Keywords
Anchorage
Bisphosphonates
Mini-implant
Orthodontics
INTRODUCTION
Mini-implants are widely recognized for their capacity to offer skeletal anchorage, as they proficiently stabilize the anchorage components and effectively impede the anterior displacement of molars.[1] The long-term maintenance of the position of mini-implants under orthodontic loading in clinical practice has been a subject of ongoing debate. Multiple investigations have documented the phenomenon of mini-implant movement within the bone with the application of orthodontic forces, while maintaining the stability of the mini-implant.[2-4] The migration of mini-implants has the potential to result in force decay and cause harm to critical structures such as the periodontium, nerves, and blood vessels.[5,6] Different surface treatments of mini-implants have been documented to alter both the surface composition and topography, resulting in an augmentation of the implant’s surface roughness and area. Thus, this has the potential to improve the interaction between the implant and bone, resulting in greater initial stability of the implant in areas with limited bone quantity and/or quality.[7,8]
Animal studies show that systemically administered bisphosphonates impede orthodontic tooth movement.[9,10] These deleterious effects of bisphosphonates have been used to an advantage through localized administration to restrict (or) control the undesired tooth movement, without interfering with the desired tooth movement.[11]
This study was done to identify if localized use of bisphosphonate as a mini-implant coating could reduce (a) mini-implant migration, (b) enhance implant stability, and (c) exhibit a favorable impact on the rate of tooth movement.
MATERIAL AND METHODS
Study design
This study followed a randomized split-mouth controlled clinical design. In each patient, one side of the maxillary arch was randomly allocated to receive a bisphosphonate-coated mini-implant, while the contralateral side received an uncoated mini-implant. Allocation of the intervention side (right or left) was performed with equal probability. Blinding was maintained for outcome assessment, wherein investigators evaluating cone beam computed tomography (CBCT) and digital model measurements were unaware of the intervention allocation. Blinding was maintained for outcome assessment, where investigators evaluating CBCT and digital model measurements were unaware of the group allocation. The research conducted was a single-blinded randomized controlled split-mouth clinical experiment, which received approval from the Institutional Ethical Review Board (SRB/ SDC/ORTHO-1906/21/TH-024). Before participating in the experiment, patients were provided with a comprehensive explanation of the proposed treatment and were required to provide informed consent. The trial was officially registered with the Clinical Trial Registry-India (CTRI/2021/11/038094). A sample size calculation was performed to achieve a statistical power of 95%, utilizing the findings from the anchorage study conducted by Liou et al. This calculation was carried out using G Power analysis software.[2] A total sample size of 15 was obtained on calculation, and an additional 3 subjects were selected to compensate for any sample attrition. The participants were randomly assigned to either the intervention group, which received bisphosphonate-coated mini-implants, or the control group, which received uncoated mini-implants. The allocation was done with equal probability for both the right and left sides in the upper arch. The participant flow in the study is indicated in the CONSORT flow chart [Figure 1]. Inclusion criteria used were (a) patients requiring orthodontic treatment aged between 15 and 40 years, (b) upper premolar extraction with maximum anchorage, (c) crowding ≤4 mm, (d) dentoalveolar proclination, (e) no systemic or metabolic diseases or periodontal problems, and (f) healthy individuals not under medication for any other ailments.

Mini-implant coating and placement
The evaporation-induced self-assembly method by Niu et al. 2018 was used to create mesoporous titanium dioxide on the titanium mini-implant surface.[12] This method of coating ensured coating stability and local drug delivery. 0.4 mg of zolendronic acid was absorbed into this mesoporous layer. The determination of drug dose was derived from the animal dosage value acquired from the investigation conducted by Dunn et al.[13]
The implants were placed once the patients were on a passive 0.019 × 0.025-inch stainless steel archwire ligated on a 0.022” slot mentalization-based treatment (MBT) metal brackets. The coated and uncoated self-drilling mini-implants of 1.6 mm wide and 8 mm long were placed in the interradicular area between the maxillary first molar and second premolars under local anesthesia, at a height that allowed the line of action of the retraction force to approximate the center of resistance of the anterior segment during en-masse retraction. The insertion height and angulation of the mini-implants were determined based on established anatomical and biomechanical considerations. The insertion angle was selected to maximize engagement of cortical bone while maintaining a safe distance from adjacent tooth roots, thereby enhancing primary stability and reducing the risk of root contact. Mini-implants were loaded immediately with an e-chain providing a force of 200 g to the retraction hook of 7–8 mm placed between the lateral incisor and canine.[14,15]
Evaluation of mini-implant displacement
The CBCT scans of the midface were performed immediately after the mini-implant was placed and again after 6 months (KODAK CARESTREAM CS 9600-16 X 17 FOV CBCT). Digital imaging and communications in medicine format was used to save the CBCT data.
Reconstructing the core three-dimensional (3D) anthropometric models (alveolar bone, teeth, and mini-implant) was done with the help of the materialise interactive medical image control system (MIMICS) medical imaging density segmentation software. By applying a thresholding method based on Hounsfield units, the MIMICS program was able to distinguish between tooth, bone, and mini-implant structures. The Standard Tessellation Language file format was used to export all 3D models.
The base of the orbit was assumed to be unchanged in every CBCT and used for superimposition. In the MIMICS software, 4 registration points were used to superimpose the models. Pre- and post-treatment CBCT scans were superimposed using four stable craniofacial landmarks: the base of the orbit, bilateral infraorbital rims, the anterior wall of the maxillary sinus, and the nasal floor. These structures are minimally affected by orthodontic treatment and allow reliable three-dimensional registration for assessing mini-implant displacement. Mini-implant deviations were assessed at the head and apex. The x, y, and z axes were reconfigured by the MIMICS program to signify bucco-palatal, distomesial, and vertical orientations, respectively. By comparing the pre- and post-treatment 3D coordinate values of the same two spots, we were able to derive the drift distances in all three directions [Figure 2]. Slice thickness used for CBCT was 0.3 mm. To assess reliability, 10% of measurements were repeated after 2 weeks, and intraclass correlation coefficients were calculated, showing values above 0.9.

Evaluation of anterior retraction
Patients were scanned in 3D using an intraoral scanner (intraoral scanner) and a 3D reverse modeling software program. The amount of space closure in millimeters at 3 months and 6 months of retraction was recorded using digital models in STL format. Retraction rate and mini-implant migration (through CBCT) were assessed at three and 6 months to capture meaningful treatment phases while minimizing radiation and avoiding short-term fluctuations from elastomeric force decay. The distance between perpendicular lines drawn from the mid palatal line to the distal surface of the canine and to the mesial surface of the second premolar was used to determine the extraction space in the digital models [Figure 3].

RESULTS
Normality of the data was tested using the Shapiro–Wilk and Kolmogorov–Smirnov tests. As the data were normally distributed, parametric tests were opted.
Mini-implant stability
Clinical evaluation showed no detectable mobility of the mini-implants in both groups at 3 and 6 months of retraction.
Mini-implant displacement
Independent “t”-test and paired t-test are described in [Tables 1 and 2]. The mean head and apex mini-implant displacement in X, Y, and Z planes in bisphosphonate-coated and uncoated mini-implant groups are represented in [Figures 4 and 5], respectively.


| Parameters | Groups | Baseline (Mean±SD) | 6 Months (Mean±SD) | #p-value |
|---|---|---|---|---|
| Head X axis | Coated | 60.21±5.96 | 60.18±5.95 | 0.058 |
| Uncoated | 60.29±5.28 | 60.27±5.29 | 0.005* | |
| ##p-value | 0.917 | 0.904 | ||
| Apex X axis | Coated | 60.88±5.35 | 60.84±5.35 | 0.117 |
| Uncoated | 60.16±5.11 | 60.13±5.12 | 0.017* | |
| ##p-value | 0.2 | 0.205 | ||
| Head Y axis | Coated | 39.53±5.31 | 39.10±5.66 | 0.06 |
| Uncoated | 41.36±3.98 | 39.24±4.02 | 0.0* | |
| ##p value | 0.072 | 0.831 | ||
| Apex Y axis | Coated | 39.94±4.40 | 39.71±4.55 | 0.053 |
| Uncoated | 41.72±3.86 | 39.91±4 | 0.0* | |
| ##p value | 0.053 | 0.749 | ||
| Head Z axis | Coated | 33.26±1.96 | 33.25±1.96 | 0.109 |
| Uncoated | 33.40±1.6 | 33.29±1.61 | 0.153 | |
| ##p value | 0.817 | 0.954 | ||
| Apex Z axis | Coated | 33.47±1.48 | 33.47±1.48 | 0.154 |
| Uncoated | 33.68±1.72 | 33.59±1.74 | 0.151 | |
| ##p-value | 0.762 | 0.857 |
SD: Standard deviation, #:indicates intra-group comparison using paired t-test, ##indicates inter-group comparison using independent t-test, *indicates statistically significant difference (p < 0.05)
| Parameter | Group | Mean | Standard deviation | p-value |
|---|---|---|---|---|
| Head X-axis deviation | Coated | 0.034 | 0.064 | 0.489 |
| Uncoated | 0.021 | 0.025 | ||
| Apex X-axis deviation | Coated | 0.039 | 0.090 | 0.664 |
| Uncoated | 0.027 | 0.039 | ||
| Head Y-axis deviation | Coated | 0.175 | 0.108 | 0.00* |
| Uncoated | 0.802 | 0.266 | ||
| Apex Y-axis deviation | Coated | 0.072 | 0.067 | 0.00* |
| Uncoated | 0.656 | 0.253 | ||
| Head Z-axis deviation | Coated | 0.005 | 0.012 | 0.116 |
| Uncoated | 0.128 | 0.292 | ||
| Apex Y-axis deviation | Coated | 0.003 | 0.008 | 0.127 |
| Uncoated | 0.096 | 0.222 |
Statistical significance level set at p< 0.05, *indicates statistically significant difference (p< 0.05)
Rate of anterior retraction
The results of independent “t”-test and paired “t”-test comparing the amount of space closure between bisphosphonate-coated and uncoated mini-implant groups at the two time intervals are described in [Table 3 and Figure 6].
| Parameters | Groups | Baseline (Mean±SD) | 3 Months (Mean±SD) | 6 Months (Mean±SD) | p-value |
|---|---|---|---|---|---|
| Retraction rate | Coated | 6.26±0.55 | 2.5±1.0 | 5.8±0.81 | 0.00* |
| Uncoated | 6.02±0.611 | 1.6±0.73 | 4.8±1.01 | 0.00* | |
| p-value | 0.28 | 0.009* | 0.007* |
The p-value indicates that there was a significant difference between the intervention and control groups at all time intervals, SD: Standard deviation, *indicates statistically significant difference (p< 0.05)

DISCUSSION
This study demonstrates that bisphosphonate-coated mini-implants exhibit reduced displacement in the mesio-distal plane and an enhanced rate of anterior retraction. These outcomes suggest that the coating may improve primary stability and anchorage preservation. Previous animal studies have shown that local bisphosphonate application can reduce tooth movement at the application site. Our findings align with prosthodontic and orthopedic research showing increased implant stability with bisphosphonate-loaded mesoporous coatings.
In our clinical setting, coated implants experienced less mesial migration, likely due to improved osseointegration. Uncoated implants showed measurable displacement that could compromise anchorage.
However, several limitations exist: First, periodontal health was not assessed throughout the study, which may influence implant displacement. Second, although CBCT imaging involves radiation exposure, it was justified in this study to enable accurate three-dimensional superimposition using stable craniofacial landmarks for assessment of mini-implant displacement. Third, our conclusions should be interpreted cautiously, given measurement limitations.
Past literature on surface modifications such as silver or hydroxyapatite coatings has shown mixed outcomes. Further long-term, controlled studies are needed to assess clinical significance and optimal coating protocols.
Several studies have consistently demonstrated that all types of bisphosphonates administered locally inhibited orthodontic tooth movement at the site of application in animal studies.[16-19] The addition of a mesoporous titanium dioxide layer that has been dip-coated with bisphosphonate has been shown to increase implant stability in several types of prosthodontic and orthopedic implants.[20,21] In this study, we employed this novel approach to form a mesoporous titanium dioxide layer on the mini-implant which is dip-coated with bisphosphonate. This modification was implemented to enhance the durability of the bisphosphonate during the self-drilling process. However, the detailed characterization of this modified coating is not within the scope of the present publication. Animal studies using bisphosphonate-loaded mesoporous coatings have demonstrated improved osseointegration, increased implant fixation, and reduced implant migration without systemic drug effects.[20,21]
After redefining the coordinate system and registering the pre- and post-treatment 3D models, the miniscrews’ 3D displacements could be calculated. The findings of the study indicated that the mini-implant exhibited displacement in the course of the force applied, whereas any displacements observed in the bucco-palatal or vertical planes were deemed insignificant. There was a significant amount of mini-implant displacement in the Y plane in the uncoated mini-implant group. While the bisphosphonate-coated mini-implant showed no significant difference, suggesting prevention of mini-implant migration. Mini-implants measuring 2×7 mm were surgically implanted into the zygomatic crest in an experiment done by Liou et al. Mini-implant tail exhibited inclination, measuring 1 mm in both millimeters in backward and forward directions. Extrusion was used on the mini-implants, which caused them to lean forward by around 1 mm.[2] Using 451 oblique lateral cephalometric radiographs, Santiago et al. found no movement in the locations of mini-implants after canine retraction.[22] Both studies by Liou et al. 2004[2] and Santiago et al. 2009[22] used two-dimensional radiographs, which is a questionable assessment method, in addition to having certain well-known limitations. El-Beialy et al. found mean mini-implant migration of 1.08 and 0.82 mm in the head and tail, respectively, while evaluating canine retraction using computed tomography (CT).[23,24] Displacement ranged from 0.17 mm at the head to 4.12 mm at the tail, with the minimum being 0.34 mm. Head mean displacements of 0.23 and 0.91 mm apically were found in a previous work by Liu et al., which were consistent with our own.[24]
Regarding the retraction rate, bisphosphonate-coated mini-implants showed a significantly greater amount of space closure, suggesting enhanced efficiency of anterior retraction due to improved anchorage control. To our knowledge, this is the first randomized split-mouth clinical trial evaluating the effect of bisphosphonate-coated mini-implants on both mini-implant displacement and the rate of en masse anterior retraction. In keeping with the MBT treatment paradigm, the rate of tooth movement was used to determine the efficacy of mass retraction rather than the retraction of individual canines. Given that the experiment was completed over the course of the full retraction period, the en-masse retraction model is preferred over the two-step retraction model, which takes more time for space closure.[15,25] Our present findings showed that there was a significant difference in the rate of space closure between the bisphosphonate-coated and uncoated groups (p < 0.05). The mean rate of space closure in the bisphosphonate-coated mini-implant group was 2.5 ± 1.0 mm at the end of 3 months and 5.8 ± 0.81 mm at the end of 6 months. The mean rate of space closure in the uncoated mini-implant group was 1.6 ± 0.73 mm at the end of 3 months and 4.8 ± 1.01 mm at the end of 6 months. The amount of space closure on the side of the bisphosphonate-coated mini-implants was significantly greater compared to the space closure on the side with the uncoated implants, showing that the reduction of implant migration has a positive effect on the rate of space closure. Since different studies use different methods of evaluation, we cannot make any direct comparisons regarding the space closure rate results. In the study conducted by Al-Sibaie and Hajeer, individuals requiring maximum anchorage experienced an average retraction rate of 0.35 mm per month over a period of 12.9 months. This investigation aimed to assess the efficacy of en-masse retraction utilizing mini-implant anchorage with individual canine retraction employing conventional anchorage.[25] When Basha et al. compared traditional retraction to retraction utilizing orthodontic micro-implants, they found that the latter took 6.0 months to achieve a mean retraction rate of 0.85 mm/month.[15] The mean retraction rates obtained in our study at the end of 3 and 6 months showed that the amount of space closure was not consistent each month. In this study, standardized hooks with an average height of 7–8 mm were used which were nearly at the level of the height of the implant placement. In this study, the significant difference in migration of the coated and uncoated implants was in the mesio-distal direction which is along the line of action of the force. It is expected that altering the line of action of the force, either by adjusting the height of the retraction hooks or by modifying the placement height of the implants, may potentially result in a change in the migration direction of the implant. Nevertheless, a comprehensive assessment of this matter would necessitate additional clinical research.
CONCLUSION
Based on the findings of the study, it was observed that the application of a bisphosphonate coating on mini-implants effectively reduced their migration in the mesio-distal direction when used for en-masse retraction purposes. In addition, it was found that bisphosphonate-coated mini-implants exhibited a significantly higher rate of space closure, indicating a greater retraction rate compared to the uncoated implant side. These findings indicate that decreasing micro-implant migration during mass anterior retraction can significantly increase the rate of gap closure.
Ethical approval:
The research/study was approved by the Institutional Review Board at Saveetha Institute of Medical and Technical Sciences, approval number SRB/SDC/ORTHO-1906/21/ TH-024, dated 16th March 2021. The trial was registered with the Clinical Trials Registry of India (CTRI) Registration No: CTRI/2021/11/038094.
Declaration of patient consent:
The authors certify that they have obtained all appropriate patient consent forms. In the form, the patients have given their consent for their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.
Conflicts of interest:
There are no conflicts of interest.
Use of artificial intelligence (AI)-assisted technology for manuscript preparation:
The authors confirm that there was no use of artificial intelligence (AI)-assisted technology for assisting in the writing or editing of the manuscript and no images were manipulated using AI.
Financial support and sponsorship: Nil.
References
- Do miniscrews remain stationary under orthodontic forces? Am J Orthod Dentofacial Orthop. 2004;126:42-7.
- [CrossRef] [PubMed] [Google Scholar]
- Drift characteristics of miniscrews and molars for anchorage under orthodontic force: Three-dimensional computed tomography registration evaluation. Am J Orthod Dentofacial Orthop. 2011;139:e83-9.
- [CrossRef] [PubMed] [Google Scholar]
- Primary migration of a mini-implant under a functional orthodontic loading. Clin Oral Investig. 2014;18:721-8.
- [CrossRef] [PubMed] [Google Scholar]
- Assessment of mini-implant displacement using cone beam computed tomography. Clin Oral Implants Res. 2011;22:1151-6.
- [CrossRef] [PubMed] [Google Scholar]
- Histologic evaluation of root-surface healing after root contact or approximation during placement of mini-implants. Am J Orthod Dentofacial Orthop. 2011;139:752-60.
- [CrossRef] [PubMed] [Google Scholar]
- Treatment of a commercial, machined surface titanium implant with H2SO4/H2O2 enhances contact osteogenesis. Clin Oral Implants Res. 2007;18:452-8.
- [CrossRef] [PubMed] [Google Scholar]
- Do silver/hydroxyapatite and zinc oxide nano-coatings improve inflammation around titanium orthodontic mini-screws? In vitro study. Int Orthod. 2023;21:100711.
- [CrossRef] [PubMed] [Google Scholar]
- Effect of alendronate on orthodontic tooth movement in rats. Am J Orthod Dentofacial Orthop. 2009;136:843-7.
- [CrossRef] [PubMed] [Google Scholar]
- Inhibition of tooth movement by osteoprotegerin versus pamidronate under conditions of constant orthodontic force. Eur J Oral Sci. 2007;115:131-6.
- [CrossRef] [PubMed] [Google Scholar]
- Effect of local administration of bisphosphonate on orthodontic anchorage-A systematic review of animal studies. J Orthod Sci. 2022;11:31.
- [CrossRef] [PubMed] [Google Scholar]
- Mesoporous titanium dioxide: Synthesis and applications in photocatalysis, energy and biology. Materials (Basel). 2018;11:1910.
- [CrossRef] [Google Scholar]
- Local delivery of osteoprotegerin inhibits mechanically mediated bone modeling in orthodontic tooth movement. Bone. 2007;41:446-55.
- [CrossRef] [PubMed] [Google Scholar]
- Assessment of changes following enmasse retraction with mini-implant anchorage compared with two-step retraction with conventional anchorage in Class II division 1 malocclusion: A randomized controlled trial. Eur J Orthod. 2014;36:275-83.
- [CrossRef] [PubMed] [Google Scholar]
- Comparative study between conventional en-masse retraction (sliding mechanics) and en-masse retraction using orthodontic micro-implants. Implant Dent. 2010;19:128-36.
- [CrossRef] [PubMed] [Google Scholar]
- The role of bisphosphonates in orthodontic tooth movement-A review. J Family Med Prim Care. 2019;8:3783-8.
- [CrossRef] [PubMed] [Google Scholar]
- Impact of bisphosphonate drug burden in alveolar bone during orthodontic tooth movement in a rat model: A pilot study. Am J Orthod Dentofacial Orthop. 2013;144:557-67.
- [CrossRef] [PubMed] [Google Scholar]
- Effects of local administration of clodronate on orthodontic tooth movement and root resorption in rats. Eur J Orthod. 2004;26:469-73.
- [CrossRef] [PubMed] [Google Scholar]
- Impact of bisphosphonate on orthodontic tooth movement and osteoclastic count: An animal study. J Int Oral Health. 2014;6:1-8.
- [CrossRef] [Google Scholar]
- Raloxifene-and alendronate-containing mesoporous titanium oxide films improve implant fixation to bone. Acta Biomater. 2013;9:7064-73.
- [CrossRef] [PubMed] [Google Scholar]
- Ex vivo alendronate localization at the mesoporous titania implant-bone interface. J Mater Sci Mater Med. 2015;26:5337.
- [CrossRef] [PubMed] [Google Scholar]
- Correlation between miniscrew stability and bone mineral density in orthodontic patients. Am J Orthod Dentofacial Orthop. 2009;136:243-50.
- [CrossRef] [PubMed] [Google Scholar]
- Loss of anchorage of miniscrews: A 3-dimensional assessment. Am J Orthod Dentofacial Orthop. 2009;136:700-7.
- [CrossRef] [PubMed] [Google Scholar]
- Finite element analysis of miniscrew implants used for orthodontic anchorage. Am J Orthod Dentofacial Orthop. 2012;141:468-76.
- [CrossRef] [PubMed] [Google Scholar]
- Root shortening in patients treated with two-step and en masse space closure procedures with sliding mechanics. Angle Orthod. 2010;80:492-7.
- [CrossRef] [PubMed] [Google Scholar]