TY - JOUR UR - https://doi.org/10.4103/apos.apos_53_18 DO - 10.4103/apos.apos_53_18 TI - Cortical Piezo-Puncture as a Minimally Invasive Method for Reducing MiniScrew Implant Insertion Torque: A Preliminary in vitro Study AU - Gomez,Juan Pablo AU - Giraldo,Lisbetd AU - Montoya,Daniela AU - Urrea,Miguel AB - Objective The objective of this study was to determine the effect of cortical piezo-puncture (CPP) on maximum insertion torque (MIT), maximum removal torque (MRT), and maximum axial load (MAL) during the insertion of self-drilling miniscrew implants (MSI), in an experimental model with proximal epiphysis of bovine tibia. Materials and Methods A comparative study was conducted using two groups of 20 self-drilling MSI inserted in intact bone (control group) and in bone with previous CPP (experimental group). MIT, MRT, and MAL of the 20 mini implants of each group were measured. Using SPSS software, Student’s t-test was applied to compare MIT and MRT and the U-test Mann–Whitney test was applied to compare MAL in both groups as well as Pearson and Spearman correlation. Results In the experimental group, average values of 12.85 (±4,32) Newton x centimeters (Ncm), 13.7 (±4,54) Ncm, and 22,474 (±895,95) gF for MIT, MRT, and MAL were found, respectively. In the control group, average values found for MIT, MRT, and MAL were 20.2 (±4,7) Ncm, 22.3 (±5,17) Ncm, and 4688,7 (±320,18) gF, respectively. Statistically significant differences were observed in MIT, MRT, and MAL between control and experimental groups (P < 0,001). Conclusions CPP before insertion of orthodontic MSI in bovine tibia significantly reduces MIT, MRT, and MAL. VL - 8 T2 - APOS Trends in Orthodontics JO - APOS Trends in Orthodontics J2 - APOS Trends in Orthodontics SN - 2321-4600 SN - 2321-1407 ER -