An alleyway
Address for correspondence: Dr. Smruti Bhusan Nanda, Department of Orthodontics, Hi-Tech Dental College and Hospital Pandra, Rasulgarh, Bhubaneswar - 751 025, Orissa, India. E-mail: smrutibhusannanda@gmail.com
This article was originally published by Wolters Kluwer and was migrated to Scientific Scholar after the change of Publisher.
How to cite this article: Nanda SB, Chalasani S, Bhatia V, Garabadu A, Varma P, Bharadwaj A. An alleyway. APOS Trends Orthod 2013;3:42-4.
Abstract
Use of microimplants in orthodontics has been increasing many folds in recent times. One of the most important aspect of microimplants stability is the position and angulations of placement. This article describes an implant placement guide that is simpler to fabricate, economical, least time consuming and a more practical for use in day-to-day orthodontic practice.
Keywords
Microimplants
placement guide
stability
INTRODUCTION
The concept of temporary anchorage devices is a relatively new application of more established clinical methodologies. Although the clinician can look to the literature for many answers, much is unknown and will only be answered by well-designed prospective basic science and clinical trials.[1] Orthodontic mini implants require a less complex surgical procedure. Still, if the quantity of interproximal bone and the inclination and proximity of the roots are incorrectly evaluated, there is a risk of root perforation.[2-4] Some authors propose surgical guides determining the implant position and inclination by means of a metallic wire connected to the orthodontic fixed appliance or a removable acrylic plate.[5,6] Another critical factor in orthodontic mini implant placement is the angle of insertion. Recommended angles of the implant to the long axes of the teeth have ranged from 10° to 20° in the mandible and from 30° to 40° in the maxilla.[7] The position and ideal orientation of the TAD relative to the surface of the bone and/or to the root surface is very important from the implant stability point of view.[8]
Fabrication
This article is about a surgical guide for mini implants that can be made from the materials available in the orthodontic office with utmost ease.
Step 1
21 × 25 SS, 16 × 22 SS welded with a spot welder (for 022 slot) [Figure 1].
17 × 25 SS, 16 × 22 SS welded with a spot welder (for 018 slot).
Welding is done with wires crossing each other at 90°.
Step 2
Another straight 0.7 mm round SS wire is bent at 90°. This wire is tied to the 16 × 22 SS wire with the help of two ligature wires [Figure 2].
Step 3
This SS wire of 0.7 mm can be fixed at any particular angulations using protactor [Figure 3].
Step 4
This wire is fixed to the bracket slot with the help of an elastic module [Figure 4].
Step 5
This device is going to guide the microimplants placement position and direction during the procedure proper as the 0.7 mm SS wire can be moved horizontally, vertically as well as the angulations is adjustable [Figure 5].
Figures 6 and 7 shows implants placed using the same guide and the IOPA radiograph of the same area with the implant, respectively.
CONCLUSION
This guide is autoclavable as well as can be cold sterilized as this does not have any acrylic part. A drop of synthetic glue can be added at the junction of the 16 × 22 SS and 0.7 mm SS just to make it immobile.
Advantages
Very economical and least time consuming
Can be sterilized
All the armamentarium and material used is readily available in orthodontic office
It guides the microimplant even during the placement, till the end.
Source of Support:
Nil.
Conflict of Interest:
None declared.
New features on the journal’s website
Optimized content for mobile and hand-held devices
HTML pages have been optimized for mobile and other hand-held devices (such as iPad, Kindle, iPod) for faster browsing speed.
Click on [Mobile Full text] from Table of Contents page.
This is simple HTML version for faster download on mobiles (if viewed on desktop, it will be automatically redirected to full HTML version)
E-Pub for hand-held devices
EPUB is an open e-book standard recommended by The International Digital Publishing Forum which is designed for reflowable content i.e. the text display can be optimized for a particular display device.
Click on [EPub] from Table of Contents page.
There are various e-Pub readers such as for Windows: Digital Editions, OS X: Calibre/Bookworm, iPhone/iPod Touch/iPad: Stanza, and Linux: Calibre/Bookworm.
E-Book for desktop
One can also see the entire issue as printed here in a ‘flip book’ version on desktops. Links are available from Current Issue as well as Archives pages.
Click on View as eBook
References
- Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop. 2007;131(4 Suppl):S68-73.
- [Google Scholar]
- Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure. ? Am J Orthod Dentofac Orthop. 2010;138:264-76.
- [Google Scholar]
- Success rate of mini and micro-implants used for orthodontic anchorage: A prospective clinical study. Clin Oral Implants Res. 2007;18:263-7.
- [Google Scholar]
- Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2007;131(4 Suppl):S82-9.
- [Google Scholar]
- Surgical guide for optimal positioning of mini-implants. J Clin Orthod. 2005;39:317-21.
- [Google Scholar]
- Insertion angle impact on primary stability of orthodontic mini-implants. Angle Orthod. 2008;78:1065-70.
- [Google Scholar]
- Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop. 2006;67:162-74.
- [Google Scholar]