Address for Correspondence: Prof. Nikhilesh R. Vaid, Ground Floor, New Blue Gardenia Housing Society, Peddar Road, Mumbai, Maharashtra, India. E-mail: orthonik@gmail.com
This article was originally published by Wolters Kluwer and was migrated to Scientific Scholar after the change of Publisher.
How to cite this article: Nikhilesh V, Pratik S, Meghna V. Oops! There goes my miniscrew!. APOS Trends Orthod 2016;6:277-80.
Any orthodontist with reasonable years in practice will come across situations where patients ingest orthodontic appliances/components, or parts of an appliance incidentally. This can, at times, constitute a serious emergency. The odds of something being inhaled versus swallowed, after passing the tongue is 1:12.
Bilder et al.[1] noted that “Objects that are ingested enter and traverse the alimentary canal and… The majority of them pass through the body without incident… Aspiration is more serious as… obstruction of the larynx or the trachea causes obstruction of the bronchial tree, which may result in pulmonary atelectasis, emphysema, or even death. An impacted foreign body in the gastrointestinal tract may lead to long-term complications such as esophageal erosion or perforation of the gut.”
Usually, we are spared the risk of aspiration because of the gag reflex, however, that can fail, and 3700 people die per year – equating to 1.2 deaths per 100,000 – due to ingestion or inhalation of foreign objects or food. The objects most commonly reported are coins, meat, buttons, and batteries. Whereas most objects pass without an incident, 10%–20% require endoscopic removal and 1% require surgical intervention. The position of the patient during treatment, sitting versus supine, is irrelevant; the literature is mixed on this issue. It goes without question that aspiration, but not so much ingestion, carries a higher risk potential for malpractice litigation.[2]
An orthodontist should be aware of these and be able to manage such a situation until specialty care arrives. We experienced an in office incident with an 11-year-old male patient who accidentally swallowed an orthodontic miniscrew. Subsequently, it did pass through the gastrointestinal tract without serious repercussions. The possible precautions that need to be taken which could prevent such accidents, and the management protocols to be followed during such emergencies are discussed in this editorial.
Miniscrews today are an indispensable armamentarium in modern-day orthodontic practices. Although an asset to the armamentarium, clinicians have experienced instances of screw loosening.[3] The fact that miniscrews could loosen and drop into the oral cavity raises the possibility and concern of accidental ingestion or aspiration of these adjuncts although they have been rarely reported in orthodontic literature. In an animal study, it was concluded that spontaneous ejection usually occurs for orthodontic anchorage screws that are ingested, and patients who swallow these screws should be carefully observed before resorting to early surgical removal.[4]
OUR TRYST
An 11-year-old male patient was being treated for malaligned upper incisors. After careful assessment, distalization was planned, and the mechanics for the same included the use of two palatal miniscrews. Two miniscrews (2 mm diameter and 8 mm length – 3M Unitek; United States) were placed in the anterior region of the palate [Figure 1a-c]. After the fabrication of an appliance for distalization, the patient was recalled for the next appointment in a week. It was observed that one of the miniscrews had loosened at its position and needed repositioning. The patient was in a supine position, and with the help of the mini-implant driver, the miniscrew was to be removed from the palate. While it was being removed, the patient turned his head to the left, which gave a push to the mini-implant driver, and accidentally, the mini implant fell into the oral cavity. The patient noticing that something had fallen immediately moved his tongue to locate it. Before the operator could pick up the mini implant from the oral cavity, the patient swallowed the mini implant.
The patient was immediately made to lie on one side and cough forcefully, but it did not help. The oral cavity was carefully inspected, and the absence of the mini implant confirmed the suspicion of the patient swallowing it. The patient was immediately sent to the Department of Radiology (under supervision) of the Institution’s general hospital and posteroanterior radiograph of the chest was made [Figure 2]. The radiograph did not show the presence of any foreign body material. Further, the anteroposterior abdominal radiograph [Figure 3] was made. This radiograph showed the presence of the miniscrew in the abdominal cavity. The laparoscopic surgeon was consulted for the same. He advised us to wait for 2–3 days, in which time he expected the spontaneous ejection of the mini implant. The patient’s parents were comforted and assured of providing all the necessary intervention if required after a waiting period of about 2–3 days. Three days after ingestion, another anteroposterior abdominal radiograph [Figure 4] was made which was clear of the foreign body material suggesting that the miniscrew had been expelled.
A PROTOCOL FOR MANAGEMENT OF ACCIDENTAL INGESTIONS
Orthodontic appliances or parts of them can compromise the airway and gastrointestinal tract because of their close proximity to the oropharynx. Any foreign body in the airway needs to be treated as a serious situation since it can be a cause of accidental death.[5]
The incidence of aspiration or swallowing of dental foreign bodies ranged from 3.6% to 27.7% of all foreign bodies injested, with the number considerably higher in children compared to adults.[6] Reported cases of ingestion of orthodontic appliances include swallowing of an expansion appliance key,[7-9] a mandibular spring retainer,[10] a fragment of maxillary removable appliance,[11] a piece of archwire,[12] a transpalatal arch,[13] and a fractured twin block appliance.[14] Most of these were managed conservatively.
Although our case did not showcase further complications, it did create anxiety in our minds until the second radiograph was made. We present certain prevention and management protocols for such situations.
PREVENTION AND MANAGEMENT PROTOCOLS TO BE FOLLOWED IN CASES OF MINISCREW INGESTION/ASPIRATION
Prevention protocols
Always place or hold a gauze pack distal to the area where the implant is being placed or removed so that it can entrap the anchorage screw if it falls into the oral cavity. Especially for palatal miniscrew placement, removal, or activations, this should be non-negotiable.
Availability of high-speed suction along with a pharyngeal tip helps in quick retrieval[15]
Good illumination in the office so that the operator can locate the site of the fallen implant with ease
A sterile long handle tweezers should be a part of the orthodontic emergency kit by the chair side, for quick removal of ingested materials
The anchorage screws could be adequately harbored by steel ligatures to the main appliance[16]
Ensure that the implant is properly secured in the driver while it is removed or placed
If any instrument is used along with the implant driver to aid in the removal of the loose microimplant, it should have a precise grip on the implant and should not, on the contrary, complicate the removal
Before the removal of an implant from areas such as palate, it should be tied with an adequate length of floss (through the eyelet) as a precautionary measure.
Management protocols
If the anchorage screw loosens with the head in supine position, turn the patient on one side to encourage it falling on the cheek rather than it dropping into the oropharynx[17]
Under good illumination, inspect the oral cavity and oropharynx for the dislodged screw and try retrieving it as soon as it is seen with the help of forceps or high-power suction[16]
If there is a suspicion of aspiration, the patient should be encouraged to cough, be given back blows and abdominal thrusts (Heimlich maneuver).[15-20] If the patient shows signs of breathlessness, then try to maintain a positive airway pressure with the help of artificial respiration and if this fails to maintain a patent airway, the object should be bypassed and an emergency airway established[21] by the emergency care medical team
If the patient does not show any acute symptoms, the patient is immediately referred for posteroanterior chest X-ray.
If the posteroanterior chest radiograph confirms the anchorage screw:
Forward viewing flexible panendoscopy can be performed under local anesthesia and is best suited for intrathoracic objects[16]
Foley’s catheter can also be used which involves passing a balloon distal to the ingested object usually under fluoroscopic guidance, inflating the balloon and then withdrawing the catheter along with the object proximally[18]
If the preceding modalities fail to remove the anchorage screw, surgical intervention is the last resort and is relatively successful.[16]
If the posteroanterior chest radiograph does not confirm the presence of the foreign body:
Anteroposterior abdominal radiograph is made. This may show the presence of the foreign body either in the esophagus (impaction usually occurs at the level of fourth cervical vertebrae)[10] or into the abdominal cavity
Although approximately 60% of ingested foreign objects pass through the esophagus and enter the stomach,[22] if the object is lodged in the esophagus, it is unlikely to pass spontaneously and has to be removed with the help of endoscopy
If the object has passed through the esophagus into the stomach, approximately 80%–90% of objects pass through the gut uneventfully.[10,23,24] Thus, a wait and watch policy can be adopted. Furthermore, serial abdominal anteroposterior radiographs should be made which are of great value in tracking the passage of the foreign object.[11] The time taken for a foreign body to traverse the intestinal tract can vary between 2 and 12 days[10]
The patients should be advised to supplement their diet with a large amount of cellulose, laxative, and foods such as bananas which aid the passage of the object through the gut[9]
Less than 1% of the foreign bodies in the gastrointestinal tract have caused a perforation.[13,25] The ileocecal junction and the sigmoid colon are the most common sites for perforation of the gastrointestinal tract.[16] In the rare case of impaction of the foreign body into the stomach, it has to be removed surgically. It is important, however, to note here that these statistics should be evaluated with caution as miniscrews, because of their shape, have a higher potential of perforating the gastrointestinal tract, compared to other orthodontic appliance components.
Every appliance and advancement in mechanotherapy comes with a caveat that the clinician is advised to take cognizance of. Nothing in orthodontics gives us an “absolute” wand to wave. Basic emergency care knowledge and prevention protocols need to be reviewed and updated by a clinician from time to time.
Vaid Nikhilesh, Shah Pratik1, Vandekar Meghna2
Editor in Chief, APOS Trends in Orthodontics,
1Department of Orthodontics and Dentofacial Orthopedics, YMT Dental College and Hospital, 2Chair and Prof, Department of Orthodontics, YMT Dental College and Hospital, Mumbai, Maharashtra, India
Address for Correspondence: Prof. Nikhilesh R. Vaid, Ground Floor, New Blue Gardenia Housing Society, Peddar Road, Mumbai, Maharashtra, India. E-mail: orthonik@gmail.com
References
- Medical emergencies in a dental office: Inhalation and ingestion of orthodontic objects. J Am Dent Assoc. 2011;142:45-52.
- [Google Scholar]
- Litigation and legislation. The patient has a big mouth. Am J Orthod Dentofacial Orthop. 2013;143(4 Suppl):S173-5.
- [Google Scholar]
- Miniscrews as orthodontic anchorage: A preliminary report. Int J Adult Orthodon Orthognath Surg. 1998;13:201-9.
- [Google Scholar]
- Ingestion of orthodontic anchorage screws: An experimental study in dogs. Am J Orthod Dentofacial Orthop. 2007;131:767-8.
- [Google Scholar]
- Inhalation of foreign bodies in children. Report of 500 cases. J Thorac Cardiovasc Surg. 1977;74:145-51.
- [Google Scholar]
- Foreign bodies of dental origin in the air and food passages. Int J Oral Maxillofac Surg. 1986;15:739-51.
- [Google Scholar]
- Accidental swallowing of orthodontic expansion appliance keys: Report of two cases. ASDC J Dent Child. 1983;50:126-7.
- [Google Scholar]
- Accidental swallowing of orthodontic expansion appliance key. Am J Orthod Dentofacial Orthop. 2011;140:266-8.
- [Google Scholar]
- Foreign body ingestion of orthodontic origin. Am J Orthod Dentofacial Orthop. 2011;139:279-83.
- [Google Scholar]
- The location and tracking of swallowed dental appliances: The role of radiology. Dentomaxillofac Radiol. 1995;24:139-42.
- [Google Scholar]
- Accidental ingestion of a fractured Twin-block appliance. Am J Orthod Dentofacial Orthop. 2011;139:123-5.
- [Google Scholar]
- Prevention and management of accidental foreign body ingestion and aspiration in orthodontic practice. Ther Clin Risk Manag. 2012;8:245-52.
- [Google Scholar]
- Accidental aspiration of a cast crown during attempted delivery. J Indiana Dent Assoc. 1988;67:22-3.
- [Google Scholar]
- A method to prevent swallowing or aspiration of cast restorations. J Prosthet Dent. 1981;46:642-5.
- [Google Scholar]
- Medical emergencies in dental practice: An update on drugs and the management of acute airway obstruction. Dent Update. 1989;16:254-6.
- [Google Scholar]
- Foreign bodies of the upper gastrointestinal tract: Current management. South Med J. 1984;77:1083-6.
- [Google Scholar]
- A lethal ectopic denture: An unusual case of sigmoid perforation due to unnoticed swallowed dental plate. J R Coll Surg Edinb. 1999;44:203-4.
- [Google Scholar]
- CT findings in gastrointestinal perforation by ingested fish bones. J Comput Assist Tomogr. 1988;12:88-90.
- [Google Scholar]